Showing 1-20 of 27 trials
NCT07534904
This study aimed to develop and clinically evaluate a novel hollow cusp fracture reducer for enhancing the precision and efficiency of closed reduction and internal fixation in patients with femoral shaft fractures and patellar fractures. A prospective randomized controlled trial was conducted at Hanzhong Central Hospital between January 2020 and January 2023. A total of 142 patients were randomly assigned to either the experimental group treated with the novel reduction device or the control group undergoing conventional manual reduction. Primary outcome measures included operative time, number of fluoroscopic images, and K-wire insertion success rate. Secondary outcomes consisted of intraoperative blood loss, length of hospital stay, fracture healing time, and postoperative complication rate. Compared with the conventional technique, the novel hollow cusp fracture reducer significantly shortened operative time and reduced the frequency of intraoperative fluoroscopy, while markedly improving the accuracy of K-wire placement. Fracture healing was also accelerated in the device group. Complication rates were comparable or lower in the experimental group. The novel hollow cusp fracture reducer is safe and effective. It improves the accuracy and efficiency of fracture reduction, lowers radiation exposure, and facilitates earlier postoperative recovery. This device demonstrates high clinical value for the minimally invasive treatment of femoral shaft and patellar fractures.
NCT03185663
The fracture of the proximal femur is a common traumatic pathology in patients aged over 70 years, associated with a mortality of 20 to 30% a year. The care is delayed emergency. During this wait, the occurrence of heel pressure ulcers is regularly found, despite wearing antiescarres slippers. Mobilization, source of pain, is also problematic. 759/5000
NCT07381725
This trial aimed to provide Level I evidence on the comparative effectiveness, safety, and functional outcomes of single versus double plating for distal femoral fractures.
NCT06382584
In 2023, oral anticoagulant treatments (anti Xa: apixaban , rivaroxaban, etc.) are tending to replace anti vitamin K treatments in many medical indications. Their prescription is increasing rapidly in the elderly. In this context, the Nimes University Hospital receives a large number of elderly patients who have suffered a fracture of the end of the femur requiring surgery and who are taking anti Xa drugs.To avoid massive intra- and post-operative haemorrhage, surgical management is postponed because of the need to suspend the treatment, allowing a return to near-normal biological haemostasis within a few days. No consensus has been reached on the withdrawal period required to authorise surgery, as the elimination kinetics of the drug are altered in this context (elderly patients, dehydration, hypovolaemia, impaired renal function). A plasma assay (threshold of \<30 to 60 ng/mL) has been proposed without any real justification. This waiting period exposes the elderly to excess mortality. Reversing these treatments by adding coagulation factors would be an attractive alternative, as it would allow surgery to be performed earlier, but this would expose patients to an increased thrombotic risk. Before considering a prospective randomised study (early vs delayed surgery on AOD), we wish to retrospectively analyse data on patients admitted to the Nimes University Hospital on anti Xa and operated on for fracture of the upper end of the femur between 1 January 2022 and 1 June 2023
NCT06652334
The goal of this observational study is to compare the regional anesthetic methods (not including general anesthesia) -spinal anesthesia, erector spinae plane (ESP) block- which are in routine practice in critically ill adult patients operated for femur fracture, in terms of intraoperative and postoperative hemodynamics and clinical course, postoperative intensive care unit stay and hospitalization durations, pain scores, postoperative morbidity, and mortality. Participants will undergo either spinal anesthesia or erector spinae plane block.
NCT06873568
Study design: monocentric, retrospective, observational and post-market clinical study. Purpose: To demonstrate the safety and performance of cephalic femoral heads. The eligible study population is represented by the entire population that underwent a hip replacement with cephalic femoral heads from 1st January 2023 onwards at the site in accordance with the indication for use of the product.
NCT01254942
This is a parallel Randomized Controlled Trial comparing two different delivery modes of post hip fracture management-a specialized Fracture Follow-up Clinic versus Usual Care alone. The Fracture Follow-up Clinic will focus on bone health and fall risk factors. The investigators will evaluate the effect of the clinic and exercise program on mobility and falls. The investigators primary hypothesis is that within the first year following a hip fracture, older adults who are assessed in the B4 Clinic and prescribed an exercise program will have significantly improved Short Physical Performance Battery (SPPB) scores compared with participants who receive usual care alone.
NCT01183078
Hypothesis: Utilization of the "wand" method will enhance improvements in drill placement, locking nail placement during tibia and femur fracture repairs, and offer less radiation exposure and less operative time. The purpose of this research study is to compare the efficacy of distal locking of intramedullary nails using a standard free-hand technique with the guided wand technique. Distal locking is the placement of screws through the intramedullary rod to hold it in place and prevent rotation. Currently, the free-hand technique is most often utilized. With this technique, the surgeon uses intraoperative x-rays in order to find the holes in the intramedullary rod to place the screws. The wand technique uses electromagnetic fields rather than x-rays to find these screw holes. The utilization of the wand technique could result in improvements in drill placement and locking nail placement as well as decrease operative time and radiation exposure.
NCT05737459
Patients over the age of 65 who underwent elective surgery for a hip fracture and were sedated during spinal anesthesia were included in the study. Patients who were given ketamine and dexmedetomidine for sedation were included in the study. The Mini Mental Status Tests of the patients measured on the first and third days of the operation in the preoperative period were determined from the hospital records and recorded.
NCT02679560
This is an investigator-initiated, single-center, randomized, patient blinded, controlled trial. The purpose of this study is to compare the effect of a fascia iliaca compartment block (FICB) using 0.2% ropivacaine vs. liposomal bupivacaine in patients with femur and/or hip fractures admitted to the University of California Davis Medical Center (UCDMC). The primary endpoint will be the total opioid requirements during the 96 hour randomization period with secondary endpoints including total daily opioid requirements for days 1-4, duration of effect and objective pain scores using the numeric rating scale (NRS) during their hospital stay.
NCT02272972
This study consists of a retrospective and a prospective part. For each part and in each of 5 clinics, one intraoperative postimplant image (lateral view) of 25 patients with pertrochanteric fractures will be assessed by 5 surgeons per clinic. There are two assessments in the retrospective part. a) before an educational intervention, b) after the educational intervention. The evaluated images at these two timepoints are identical. In the prospective part, the surgeons apply their new knowledge from the educational intervention. They perform the positioning of the patient during the intraoperative fluoroscopy and record the image according to the teaching material. One postimplant image of each patient will be used for the evaluation. At all three timepoints of image assessment, a questionnaire with the same set of 7 criteria (Q1-Q7) for assessing the radiographs is used. The criteria refer to the content of the educational material.
NCT00644397
Internal fixation of femur fractures improves alignment and provides stability to the bone and the surrounding soft tissues. This generally allows for early motion of the adjacent joints; thus maximizing overall function of the limb. Open reduction and internal fixation with plates and screws is the standard method that has been used in the treatment of distal femoral fractures. One common traditional method of internal fixation is the 95-degree angled blade plate. Recent advances in technology for distal femur fractures include the LCP™ Condylar Plate. This implant differs from the blade plate, because the LCP offers multiple points of fixed angle contact between the plate and screws in the distal femur. The introduction of plates with the option of locked screws has provided means to increase the rigidity of fixation in osteoporotic bone or in periarticular fractures with a small distal segment, and the LCP may be technically easier to apply than the blade plate. To the investigators' knowledge, there have been no published clinical or biomechanical studies specific to the LCP Condylar Plate, although the early results of LCP implants for other fractures are promising. The investigators believe that locked plating represents a valuable advancement in fracture treatment. However, the limitations of this new technology and the indications for its use have not been completely elucidated. Furthermore, the cost of the new technology is approximately seven times more than the traditional treatment. This is a randomized, prospective, multi-center study to compare the blade plate and the LCP in the distal femur. All patients 16 years of age or older, regardless of race or gender, with a supracondylar fracture of distal femur will be considered. Whether patients are treated with a blade plate or/and LCP, they will be receiving standard orthopedic care for their injury. Neither of these methods currently places a patient at increased surgical or post-surgical risk for problems with infection, nonunion, malunion, or other complications. Because of the study, early and late complication rates and functional outcomes after these treatments may be better defined, allowing for optimization of care of people with these injuries in the future. This should reduce not only direct and indirect costs to the individual, but also costs to society.
NCT02155595
The purpose of this protocol is to determine the risk of atypical femoral shaft (thigh bone) fractures after long term fracture prevention therapy with a class of drugs called "bisphosphonates", colloquially referred to as Alendronate, risedronate, Ibandronate, and Zoledronate. In addition, the study is designed to find out which patient is most likely to develop this potential life changing complication and why. Finally, the results of this study will help clinicians to better understand the reason and thus tailor patient specific treatments…i.e., "the right treatment for the right patient for right duration."
NCT03800186
This study aimed to determine the influence of ageing on the incidence and site of femoral fractures in trauma patients, by taking the sex, body weight, and trauma mechanisms into account.
NCT01294098
The purpose of this study is to examine the efficacy of the use of Marcaine in femoral nerve blocks and hematoma blocks for post operative pain relief for femoral shaft fractures in a pediatric population.
NCT00626470
Fractures just below the hip often are treated with a so called Gliding Screw and Plate (DHS). Recently a new additional plate called a Trochanter Support Plate (TSP) which attaches to the DHS has become available which is claimed to give extra support to the fracture. In a prospective randomised study we wish to test the hypothesis that the TSP does not give any additional stability to the fracture treated with the DHS.
NCT00872573
The purpose of this study is to monitor the stability of the C-Stem™ AMT hip within the thigh bone when used in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical, standard x-ray assessments and special x-rays which allow the stability of the implant to be determined.
NCT00208377
The purpose of this study is to monitor the performance and determine the metal ion release of the DePuy ASR™ System in the treatment of patients with hip joint disease requiring hip resurfacing surgery. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. A subset of patients will also have blood samples taken at regular intervals to allow the metal ion levels to be determined and undergo scans to allow the bone mineral density of the bone surrounding the implant to be monitored. DePuy decided to close this Study in 4Q 2009. The Study was terminated with effect from December 2010 to allow for the completion of the 5 year follow up assessments. Please note that subsequent to this decision DePuy voluntarily recalled the ASR products on 24 August 2010. Additional information regarding this voluntary recall and the follow-up of patients affected by the recall can be found at the following links http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON079157 and http://www.depuy.com/countries\_list.
NCT00872794
The purpose of this study is to monitor the performance and determine the metal ion release of the DePuy ASR™ System in the treatment of patients with hip joint disease requiring hip resurfacing surgery. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. A subset of patients will also have blood samples taken at regular intervals to allow the metal ion levels to be determined and undergo scans to allow the bone mineral density of the bone surrounding the implant to be monitored. DePuy decided to close this Study in 4Q 2009. The Study was terminated with effect from November 2010 to allow for the completion of the 5 year follow up assessments. Please note that subsequent to this decision DePuy voluntarily recalled the ASR products on 24 August 2010. Additional information regarding this voluntary recall and the follow-up of patients affected by the recall can be found at the following links http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON079157 and http://www.depuy.com/countries\_list.
NCT00872066
The purpose of this study is to monitor the performance of artificial hip joints implanted with two different bone cements, SmartSet® HV and SmartSet® GHV, in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be randomly allocated to SmartSet® HV or SmartSet® GHV and will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments