NCT07206134
Twelve adult patients with mandibular fractures in the mental region were enrolled and randomly divided into two equal groups. Group I received fixation using custom-designed modified omega bone plates, while Group II was treated with conventional titanium miniplates following Champy's technique. Virtual surgical planning and 3D printing technology were used to fabricate customized plates in Group I. Clinical and radiographic assessments were conducted immediately, at 1 week, 3 months, and 6 months postoperatively. Parameters evaluated included soft tissue healing, pain, facial edema, lower lip paresthesia, maximal mouth opening, occlusion, fracture stability, and hardware integrity.
NCT06939010
the study aims to compare 3D Interlocking miniplates with conventional miniplates in management of mandibular parasymphyseal fractures both clinically and radiographically.
NCT06883331
A randomized clinical study that aims to assess the validity of the use of computer guided technique in the proper placement of IMF screws in mandibular fractures
NCT04283981
The purpose of this trial is to compare operating room time between conventional treatment techniques \[without Virtual surgical Planning (VSP)\] versus treatment with use of Virtual surgical Planning (VSP) in patients that undergo mandibular reconstruction via open reduction internal fixation (ORIF).
NCT06338982
The goal of this clinical trial is to investigate the hypothesis that there are none difference in the treatment result of orthognathic surgery on the lower jaw, with interoperative wisdom tooth removal rather than preoperative wisdom tooth removal. In patients with severe dental malocclusion combined with a dentofacial deformity. The main question it aims to answer are: • Is there a difference in the degree of complication and the patient's perception, with inter-operative wisdom tooth removal rather than pre-operative wisdom tooth removal. Participants will be will be divided into two groups, with one group having their wisdom teeth removed 6 months before their jaw moving surgery and the other group having their wisdom teeth removed in connection with their jaw moving surgery.
NCT02081885
Introduction After a mandibular fracture where bone has been lost, a number of complications and challenges are presented in trying to solve them. These defects are mainly classified into two groups: functional and cosmetic. The functional defects are incompetence of the lower lip, salivary incontinence, severe difficulty chewing and swallowing, temporomandibular joint disorders and difficulty in pronouncing words. Esthetically facial asymmetry is produced with collapse of the affected side. Unreconstructed jaw retrusion and tends to offset the affected side, there is a change in mandibular movements, which, previous vertical movements are replaced by oblique or diagonal movements controlled by a single temporomandibular joint. It also presents a limitation in motility and lingual force, besides proprioception disorder left by the inferior alveolar nerve The loss of bone in mandibular fractures, is one of the great challenges facing maxillofacial surgery and unfortunately increasingly common. That's why they have done and are still doing research for the development of biomaterials, all with the purpose of trying to solve this problem by offering the patient better results than those obtained in the past, restoring both function and facial aesthetics according to each case
NCT05647460
* Preoperative CT. * Virtual reduction of broken segments on software. * Gain occlusion. * Design surgical screw holes locating guide. * Design the custom-made plates. * Print the screw holes locating guide and the custom-made plate. under general anesthesia the parasymphseal fracture will be reduced using screw holes locating guide and the custom-made plates.
NCT05467618
This study compared the surgical approach to the lower jaw fractures, an approach from the face and an approach from inside the mouth were used and compared for the outcomes.
NCT04729036
Twenty-five patients with mandibular angle fracture were subjected to reduction and fixation through intra-oral open reduction and semi-rigid min plate fixation near the superior border of the mandible at Champy's osteosynthesis line. The linear inter-fragmentary gap was measured at the inferior border of the mandible after fixation of the fractured bony segments in the final aligned position immediately postoperative on a panoramic radiograph for the mesio-distal plane and a cone beam computed tomography for the bucco-lingual plane to assess any lingual splay. The healing process was clinically followed for 3 months postoperatively for any complications and/or patient complains
NCT04719325
14 patients having recent anterior mandibular fracture divided into two groups. Group A has 6 patients and treated using Herbert bone screw, and group B has 6 patients and treated using lag screw. Clinical follow-up was conducted after 24-hours, one, four, six, and twelve weeks. In addition, a radiographic investigation was performed after twelve weeks to estimate the mean bone density across the fracture line.
NCT04396054
This study is a prospective randomized controlled clinical trial. It was performed on sixteen patients with anterior mandibular fractures, to compare Double Y-shaped plates and Lag Screws in fracture fixation from clinical and radiographic perspectives.
NCT03761524
The aim of the study to evaluate the effect of customized V pattern plate fixation versus a conventional superior-inferior mini plates fixation of mandibular angle fracture on mouth opening and radio graphical parameters.
NCT03714035
this study aims to correlate mandibular indices and different ages in a sample of Egyptian population.
NCT03608891
The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific computer guided titanium plates versus the conventional titanium mini plates regarding accurate reduction and fixation of mandibular body fractures, reducing the operating time, achieving precise bone alignment and reducing the plate palpability.
NCT03494309
Patients with mandibular sub-condylar fractures underwent either either open reduction with internal fixation (ORIF) or closed reduction with external fixation (CREF) and were followed up for 6 months to assess treatment adequacy with the hypothesis that ORIF is superior to CREF.
NCT02466269
A new surgical approach, denoted as the supratemporalis approach, was designed to treat diacapitular condylar fractures of the mandibular condyle.This approach prevented facial nerve injury and did not increase the frequency of other complications. Therefore, the investigators suggest this surgical procedure as a routine and safe approach to diacapitular condylar fractures, which can also be applied to temporomandibular joint(TMJ)and to the zygomatic arch.
NCT02755922
Mandible fractures are a common cause of facial injury in adults. The autologous mesenchymal stem cell (AMSC) transplantation, is proposed as an alternative to the conventional graft treatment, improving bone neoformation.The objective was to evaluate the effectiveness of AMSCs application in mandibular fractures to reduce regeneration time and increase bone quality.