Detailed description of device and surgical procedure: During the surgical procedure, the colorectal anastomosis will be created using the C-REX RectoAid Cath (Carpo Novum AB, Halmstad, Sweden). The C-REX devices are CE-marked and used in its intended purpose in this trial. The C-REX RectoAid Cath is a refined anastomotic device that facilitates the construction of an inverted serosa-to-serosa adaptive colorectal anastomosis where the bowel ends are held together by snap-locking a proximal and distal silicone anastomotic ring. The C-REX devices can be used in both open and minimally invasive procedures. The proximal limit for C-REX RectoAid Cath is 25 cm above the anal verge and the distal limit is formed by the anal ring. The anterior resection using the C-REX RectoAid Cath is performed by experienced colorectal surgeons who received training to use the C-REX device from an experienced Clinical Field Trainer from Carpo Novum AB. After bowel resection and measuring of the lumen using the C-REX Test Device, the proximal ring is placed using the C-REX LapAid. This device ensures that the colonic wall is folded around the anastomotic ring. Once this colonic ring is in position, the anvil is connected whereby catheters are placed into the colonic lumen. Subsequently, the C-REX RectoAid can be inserted transanal. In similarity to ordinary stapler devices, a concealed trocar becomes visible by rotating the knob on the base of the handle of the C-REX RectoAid. When possible, the stapler line of the transected proximal rectal stump is invaginated into the distal anastomotic C-REX ring and thus removed at firing of the RectoAid instrument. The trocar and proximal anvil are connected and by turning the knob clockwise, the gap between the anvil and the head of the instrument is closed. After firing the device, the two anastomotic rings are connected and the anastomosis is created. The four integrated catheters will be extracted simultaneous with the RectoAid instrument and can be used to measure the Anastomotic contact pressure (ACP) to validate the anastomosis. These catheters are in direct contact with the anastomotic healing site. When the anastomotic rings detach during the healing process by necrosis, after approximately 10 days, the anastomotic ring loosens from of the intestinal wall and is expelled with the feces.
Age
18–any
Sex
ALL
Healthy volunteers
Not accepted