Study design: Stratified randomized controlled trial, parallel group Population: Sepsis-associated AKI requiring KRT patient Hospital: Ramathibodi hospital and Chakri Naruebodindra Medical Institute (CNMI) Randomization: Stratified Randomization based on hemodynamics of the patient (envelope technique)
• In hemodynamic unstable group (allocation 1:1) Sustained low-efficiency diafiltration (SLED-f) vs. Sustained low-efficiency dialysis (SLED) SLED-f is representative of convection-based KRT in critically ill patient. Dialysis prescription: Nikkiso DBB-05 (Tokyo Japan) Hemodiafiltration machine, High-flux polysulfone (Elisio 190HR) dialyzer (Nipro, Japan), minimum blood flow rate (BFR) 200-250 ml/min, minimum dialysate flow rate (DFR) 300 ml/min, dialysate Ca 2.5-3.5, Na 135-140, HCO3 35-38 mmol/L, dialysate temperature 35.5-36.5oC, dialysis duration 4-8 hrs, heparin 500 unit/hr if no contraindication, replacement fluid (online pre-dilution technique) with minimum flow rate 100 ml/min SLED is representative of diffusion-based KRT in critically ill patient which is currently a standard of dialysis care in hemodynamic unstable AKI patient.
Dialysis prescription: Fresenius 4008 (Bad homburg, Germany) hemodialysis machine, low-flux polysulfone (Elisio 170L) dialyzer (Nipro, Japan), minimum BFR 150-250 ml/min, minimum DFR 300 ml/min, dialysate Ca 2.5-3.5, Na 135-140, HCO3 35-38 mmol/L, dialysate temperature 35.5-36.5 oC, dialysis duration 4-8 hrs, heparin 500 unit/hr if no contraindication
• In hemodynamic stable group (allocation 1:1) Online hemodiafiltration (OL HDF) vs. Intermittent hemodialysis (IHD) OL HDF is representative of convection-based KRT in hemodynamic stable AKI patient Dialysis prescription: Nikkiso DBB-05 (Tokyo, Japan) or Fresenius 5008 (Bad homburg, Germany) online-hemodialysis machine, high-flux polysulfone (Elisio 190HR) dialyzer (Nipro, Japan), minimum BFR 200-300 ml/min, DFR 500 ml/min, dialysate Ca 2.5-3.5, Na 135-140, HCO3 35-38, dialysate temperature 35.5-36.5oC, dialysis duration 4 hrs, heparin 500 unit/hr if no contraindication, replacement fluid (online pre-dilution technique) with minimum flow rate 100 ml/min IHD is representative of diffusion-based dialysis treatment which is currently a standard of dialysis care in hemodynamic stable AKI patient.
Dialysis prescription: Fresenius 4008 (Bad homburg, Germany) hemodialysis machine, low-flux polysulfone (Elisiio 170L) dialyzer (Nipro, Japan), minimum BFR 200-300 ml/min, DFR 500 ml/min, dialysate Ca 2.5-3.5, Na 135-140, HCO3 35-38, dialysate temperature 35.5-36.5 oC, dialysis duration 4 hrs, heparin 500 unit/hr if no contraindication