Finding studies
Finding studies
Take this into the appointment.
Saves the questions and what to expect into your notes, next to the visit they belong to.
Lead
Seoul National University Hospital
* Primary objective: to compare the screening performance of DW MRI versus mammography alone or combined mammography and ultrasonography in women with PHBC. * Secondary objective: to compare the tumor and patient characteristics detected by DW MRI and combined mammography and ultrasonography in women with PHBC. * This is a prospective, single center, observational cohort study. * A total of 1694 women will be enrolled in this study. * Two latest 3.0 T MRI scanners with dedicated 16- or 18-channel bilateral breast coil are used for DW MRI. For DW MRI screening, the high-resolution echo-planar imaging sequence is designed to have an in-plane resolution of 1.3 x 1.3 mm and a slice thickness of 3 mm. Three b values of 0, 800, and 1200 sec/mm2 are used and ADC maps are generated based on the b=0 and 800 sec/mm2 DW MRI data. The DW MRI images are reconstructed into single summation images with maximum-intensity projections (MIPs) in the sagittal and axial planes. In addition, T1-weighted imaging sequence is also obtained with in-plane resolution of 1.0 x 1.0 mm and a slice thickness of 1 mm. * All patients with PHBC undergo digital two-dimensional mammography and physician-performed whole-breast ultrasonography on the same day. DW MRI and conventional imaging (mammography and ultrasonography) are alternatively scheduled at 6-month intervals and the order has been randomized. * Mammography alone, combined mammography and ultrasonography, and DW MRI will be interpreted independently according to the Breast Imaging Reporting and Data System (BI-RADS) and likelihood of malignancy (Score range, 0%-100%) by trained radiologists. DW MRI interpretation guidelines to be used in this study are based on both qualitative and quantitative assessments. Radiologists are required to successfully complete a training case series of 100 DW MR studies prior to interpreting the DW MRI. * A negative examination result is defined as a final assessment BI-RADS category of 1, 2, 3 and a positive examination result is defined as a final assessment BI-RADS category of 4 or 5. * Biopsies of DW MRI-detected lesions are performed under ultrasonography guidance whenever possible or with MR guidance if there is no correlative ultrasonography finding. Pathology of core or surgical biopsy and 1 year follow up is the reference standard.
Age
25–any
Sex
FEMALE
Healthy volunteers
Not accepted
