Rationale:
Hypoxemia is frequently observed in COPD and thus can negatively impact exercise tolerance. Supplemental oxygen or long-term oxygen therapy is recommended to ensure that the patient is still able to manage his daily life. Usually, oxygen supplementation is delivered using constant flow rates during day- and nighttime or as needed. However, studies have shown, that auto-regulated oxygen flow systems (FreeO2) may enhance the patients endurance, lower the time in severe hypoxemia and increase the time spent within the SpO2 target range.
Aim of this study is to investigate the effects off an auto-regulated oxygen flow system in hypoxemic COPD patients on the patient´s endurance, the oxygen saturation, the pCO2 blood level as well as on heart rate and breathing frequency compared to the effects off the prescribed constant flow (according to the British Thoracic Society Guidelines for Home Oxygen Use in Adults) during an endurance shuttle walk test (ESWT). Additionally, patients experience, e.g. comfort and Preference of the Oxygen-delivery System will be documented.
Design:
This study is a randomized, controlled cross-over trial. Following an initial incremental shuttle walk test (ISWT) in order to determine the participants individual maximal walking capacity, the participant will perform 2 endurance shuttle walk tests (ESWT) at 85% of the maximal walking rate. In randomized order, the participants will perform one ESWT with constant flow as prescribed and one ESWT with the auto-regulated oxygen flow system.