Flow-Mediated Dilation (FMD) - Subjects will lie in the supine position for 20 minutes to obtain hemodynamic steady state. A blood pressure cuff (Hokanson) will be placed around the forearm (distal to the Doppler transducer) and rapidly inflated to 250 mmHg for 5 minutes (circulatory arrest). Simultaneous ultrasound images of the vessel (B-mode) and Doppler waveforms will be collected 10 seconds prior to and for 2 minutes following deflation of the cuff. All B-mode images will be analyzed using automated edge detection software (Medical Imaging Applications), while intensity weighted velocity spectra segments will be saved to the GE Logiq 7 hard drive for off-line blood velocity waveform analysis. P.I. has utilized the traditional method of brachial artery flow-mediated dilation (FMD) induced by reactive hyperemia to assess vascular endothelial function in populations ranging from young healthy adults to older adults with pathological conditions.
Spygmocor - Pulse Wave Velocity (PWV) - A Spygmocor® device will be used at baseline and following each protocol to assess PWV. PWV analysis provides a non-invasive assessment of arterial stiffness. Increased arterial stiffness is known to be associated with cardiovascular disease. The participant is required to lie in a resting position for approximately 30-45 minutes. The research assistant will place ECG electrode sensors at the carotid, femoral, radial and distal artery locations. A highly sensitive pen-like device, called a tonometer, is then gently applied to record the velocity of the blood flow between each of the points.